45
BATTERY CHECK CARD – HOUR METER
1. Verify that when turning on the machine the battery check card has the
following starting sequence:
• Turning on of the LED which correspond to the set-up (red LED = “0”).
• Turning on of all the LEDs (check of the lamps)
• Turning on of the LEDs depending on the charge of the battery
2. Verify the hour meter functionality
• To verify which is the set-up you turn on the machine and check which
is the first LED that turns on. Counting the LEDs since the left side any
LED correspond to a position and the LED which turn on correspond to
the current set-up.
• Verify that if the machine uses wet cell batteries the adjustment is on
position 1.
• Verify that if the machine uses GEL batteries the adjustment is on posi-
tion 4.
WARNING: A wrong set-up of the battery control card can
compromise the battery efficiency and damage then in ir-
reversible way.
1. Verify the cleanness and functionality of the solution filter under the
solution tank plug.
2. Check cleanness and sealing of the solution filter.
3. Confirm that solution tank is completely filled.
4. Verify the sealing of the hoses, solenoid valve and the water valve.
5. Verify that the solution, with valve completely open, falls continuously
on the floor.
WATER PLANT INSPECTIONS